email:sales01@weitefanuc.comPengontrol FANUC NC, penguat servo, catu daya servo, papan kontrol, papan sirkuit kontrol tunggal (motherboard, papan CPU, bidang belakang, papan plug-in, papan daya, papan utama, papan I / O, papan AXIS, papan SPIF, papan CRT , papan PSU, papan FSRM, papan SRAM, papan DRAM, papan daya FSRM), dll.
| A06B Seri | A06B-6066-H244 | A06B-6078-H211 | A06B-6078-H306 | A06B-6079-H105 | A06B-6087-H137 |
| A06B-6079-H206 | A06B-6079-H208 | A06B-6079-H209 | A06B-6080-H301 | A06B-6087-H130 | |
| A06B-6080-H305 | A06B-6080-H307 | A06B-6080-H309 | A06B-6081-H103 | A06B-6087-H115 | |
| A06B-6087-H126 | A06B-6089-H203 | A06B-6093-H101 | A06B-6093-H102 | A06B-6140-H015 | |
| A06B-6093-H111 | A06B-6093-H151 | A06B-6102-H211 | A06B-6102-H215 | A06B-6134-H203 | |
| A06B-6102-H520 | A06B-6110-H026 | A06B-6110-H030 |
Diskriminasi dan perbaikan kesalahan umum di FANUC.
Kegagalan SVM: Tampilan LED 2, cara menghilangkan alarm. Kegagalan SPM: Tampilan LED 19, bagaimana cara menghilangkan alarm?
Kode alarm SVM 2.
(1) isi: konverter frekuensi mengontrol tegangan rendah catu daya.
(2) penyebab utama dan cara eliminasi.
(a) memastikan tegangan masukan 3-fasa penguat (harus lebih besar dari atau sama dengan 0,85 kali tegangan masukan pengenal).
(b) mengonfirmasi keluaran tegangan catu daya 24V dari PSM (normal: 22.8V atau lebih besar).
(c) konfirmasi Konektor, Kabel (CXA2A/B).
(d) ganti SVM.
Kode alarm SPM 19, 20.
Tegangan offset rangkaian pendeteksi arus fasa U (kode alarm 19) dan fasa V (kode alarm 20) terlalu besar.Deteksi saat dihidupkan.
Apabila terjadi alarm, harap ganti SPMnya. Ketika papan sirkuit cetak kontrol SPM baru saja diganti, harap konfirmasikan pemasangan konektor antara unit daya dan papan sirkuit cetak kontrol SPM.