E - Mail:sales01@weitefanuc.comPengontrol Fanuc NC, Amplifier Servo, Catu Daya Servo, Papan Kontrol, Papan Sirkuit Kontrol Tunggal (Motherboard, Papan CPU, Backplane, Plug - In Board, Power Board, Main Board, I / O Board, Papan Axis, Papan SPIF, CRT Board , Dewan PSU, Dewan FSRM, Dewan SRAM, Dewan DRAM, Dewan Daya FSRM), dll.
A06B Seri | A06B - 6066 - H244 | A06B - 6078 - H211 | A06B - 6078 - H306 | A06B - 6079 - H105 | A06b - 6087 - H137 |
A06B - 6079 - H206 | A06B - 6079 - H208 | A06B - 6079 - H209 | A06B - 6080 - H301 | A06b - 6087 - H130 | |
A06B - 6080 - H305 | A06B - 6080 - H307 | A06B - 6080 - H309 | A06B - 6081 - H103 | A06b - 6087 - H115 | |
A06B - 6087 - H126 | A06B - 6089 - H203 | A06B - 6093 - H101 | A06B - 6093 - H102 | A06B - 6140 - H015 | |
A06B - 6093 - H111 | A06B - 6093 - H151 | A06B - 6102 - H211 | A06B - 6102 - H215 | A06B - 6134 - H203 | |
A06B - 6102 - H520 | A06B - 6110 - H026 | A06B - 6110 - H030 |
Diskriminasi dan perbaikan kesalahan umum di FanUC.
Kegagalan SVM: LED Display 2, Cara Melepas Alarm. Kegagalan SPM: LED Display 19, Bagaimana cara menghapus alarm?
Kode Alarm SVM 2.
(1) Konten: Konverter frekuensi mengontrol tegangan rendah catu daya.
(2) Penyebab utama dan metode eliminasi.
(a) Mengonfirmasi tegangan input 3 - fase dari penguat (harus lebih besar dari atau sama dengan 0,85 kali tegangan input terukur).
(B) Mengonfirmasi output tegangan catu daya 24V dari PSM (normal: 22.8V atau lebih besar).
(c) Konfirmasi konektor, kabel (CXA2A/B).
(d) Ganti SVM.
Kode Alarm SPM 19, 20.
Tegangan offset fase U (kode alarm 19) dan v fase (kode alarm 20) Sirkuit deteksi arus terlalu besar.
Saat alarm terjadi, harap ganti SPM. Ketika papan sirkuit cetak kontrol SPM baru saja diganti, harap konfirmasi penyisipan konektor antara unit daya dan papan sirkuit cetak kontrol SPM.